International Journal of Science and Research (IJSR)

International Journal of Science and Research (IJSR)
Call for Papers | Fully Refereed | Open Access | Double Blind Peer Reviewed

ISSN: 2319-7064

Downloads: 141 | Views: 215 | Weekly Hits: ⮙1 | Monthly Hits: ⮙1

Research Paper | Dental Science | India | Volume 9 Issue 1, January 2020 | Rating: 7 / 10


Comparison of Canal Transportation and Remaining Dentin Thickness using Different NiTi Systems with CBCT - An in Vitro Study

Shireesha Thota | Jayaprada Reddy Surakanti | Ravichandra Polavarapu Venkata | Harikumar Vemisetty | Rajani Punna | Srujana Chandragiri


Abstract: Context: Controlled, uniformly tapered radicular preparation is a great challenge in endodontics. This study evaluated the shaping ability of three different instrumentation techniques. Aims: The aim of this study was to compare canal transportation and remaining dentin thickness of hand NiTi K files, ProTaper and WaveOne rotary systems using CBCT. Settings and Design: This study was conducted in the Department of Conservative Dentistry & Endodontics, Kamineni Institute of Dental Sciences, Narketpally in association with the secunderabad dental imaging, Secunderabad. Methods and Material: 30 mesiobuccal roots of maxillary first molars were taken and assigned to 3 experimental groups (n=10). Pre instrumentation and post instrumentation CBCT images of root cross sections at 3, 5, 7 and 9mm from apex to the canal orifice were obtained. Canal transportation and remaining dentin thickness were evaluated using DICOM software. Statistical analysis used: Data was statistically analyzed using SPSS version 19.0 software, One-way analysis of variance and Post hoc comparison for statistical significance. Results: It was observed that ProTaper has shown significantly more canal transportation when compared to hand NiTi K files and WaveOne at all the sections. Hand NiTi K files has shown significantly more dentin thickness compared to ProTaper and WaveOne at all sections. Conclusions: The WaveOne NiTi system has maintained the canal anatomy with less amount of canal transportation when compared with the ProTaper system and Hand NiTi K flex files in the apical third.


Keywords: Canal transportation, Cone beam computed tomography, Nickel Titanium, ProTaper, Reciprocating motion, WaveOne


Edition: Volume 9 Issue 1, January 2020,


Pages: 548 - 551

Rate this Article


Select Rating (Lowest: 1, Highest: 10)

5

Your Comments

Characters: 0


Type Your Registered Email Address below to Rate the Article


Verification Code will appear in 2 Seconds ... Wait

Top