International Journal of Science and Research (IJSR)

International Journal of Science and Research (IJSR)
Call for Papers | Fully Refereed | Open Access | Double Blind Peer Reviewed

ISSN: 2319-7064


Downloads: 118 | Weekly Hits: ⮙1 | Monthly Hits: ⮙1

Research Paper | Medical Surgical | India | Volume 7 Issue 5, May 2018


Comparison of Sirius Corneal Topographer and Digital Callipers to Determine Corneal White-To-White Diameter in Phakic Intraocular Lens Implantation

Atul Gupta [2] | Ashish Rander | S. Sravanthi [2]


Abstract: Precise measurement of the white-to-white diameter is important for the selection of an ideal sized phakic intraocular lens. Purpose The purpose of this study was to compare the white-to-white measured using Sirius corneal topographer with that of white-to-white measured manually using digital callipers. Method A prospective observational study conducted in a refractive eye care centre from November, 2016 to April, 2017. Forty eyes of twenty patients were included in the study. The corneal white to white diameter was measured using both digital callipers and Sirius corneal topographer. Statistical analysis was performed using SPSSv20.0. Result The mean corneal diameter with the Sirius corneal topographer and the digital callipers was 12.18 mm and 11.91 mm respectively. Based on comparison done by paired t-test, corneal diameter measurements using digital callipers were 0.27 mm smaller than the measurements obtained using Sirius topography device. Conclusion The white-to-white measurement using digital callipers is lesser in comparison to the measurement using the Sirius corneal topographer. The sizing of the phakic IOL was acceptable when the measurements using digital callipers were taken, providing an optimal vault. Measuring the white-to-white diameter of the cornea using the calliper is a reliable method and prevents over or under sizing of the phakic IOL.


Keywords: corneal white to white diameter, Sirius, digital callipers, phakic IOL


Edition: Volume 7 Issue 5, May 2018,


Pages: 1581 - 1585


How to Download this Article?

You Need to Register Your Email Address Before You Can Download the Article PDF


How to Cite this Article?

Atul Gupta, Ashish Rander, S. Sravanthi, "Comparison of Sirius Corneal Topographer and Digital Callipers to Determine Corneal White-To-White Diameter in Phakic Intraocular Lens Implantation", International Journal of Science and Research (IJSR), Volume 7 Issue 5, May 2018, pp. 1581-1585, https://www.ijsr.net/get_abstract.php?paper_id=ART20182799

Similar Articles with Keyword 'corneal'

Downloads: 2 | Weekly Hits: ⮙1 | Monthly Hits: ⮙1

Masters Thesis, Medical Surgical, India, Volume 12 Issue 11, November 2023

Pages: 1724 - 1730

Efficacy of Liquid Artificial Tears versus Gel Artificial Tears to Prevent Dry Eye among Critically Ill Patients in Intensive Care Units - A Randomized Control Trial

Slingringdi Kemprai | M. J. Kumari | Subashini Kaliaperumal

Share this Article

Downloads: 6 | Weekly Hits: ⮙1 | Monthly Hits: ⮙1

Case Studies, Medical Surgical, India, Volume 12 Issue 12, December 2023

Pages: 1056 - 1057

Small Incision Cataract Surgery Modified Techniques for New Era

Dr. K. Siva Subbarao [2]

Share this Article
Top