Features of Streamer Discharge in Geiger-Muller Counters
International Journal of Science and Research (IJSR)

International Journal of Science and Research (IJSR)
Call for Papers | Fully Refereed | Open Access | Double Blind Peer Reviewed

ISSN: 2319-7064


Downloads: 111 | Views: 415

Research Paper | Aerospace Engineering | Russia | Volume 6 Issue 11, November 2017 | Popularity: 6.2 / 10


     

Features of Streamer Discharge in Geiger-Muller Counters

V. I. Razin


Abstract: The paper considers one of the understudied aspects of the use of low-voltage halogen counters of the Geiger-Muller, associated with the choice of the operating point voltage in the middle of the plateau of the counting characteristics. It is shown that the difficulties can be caused in determining of the beginning of counting characteristics by the appearance of streamer discharge pulses in a zone of limited proportionality to the transition to a stable corona discharge. The use of the Raether criterion to estimate the necessary and sufficient conditions for the appearance of a streamer makes it possible to introduce some clarity into the essence of this phenomenon.


Keywords: Streamer discharge, Geiger-Muller counter, Electron multiplication


Edition: Volume 6 Issue 11, November 2017


Pages: 109 - 110



Please Disable the Pop-Up Blocker of Web Browser

Verification Code will appear in 2 Seconds ... Wait



Text copied to Clipboard!
V. I. Razin, "Features of Streamer Discharge in Geiger-Muller Counters", International Journal of Science and Research (IJSR), Volume 6 Issue 11, November 2017, pp. 109-110, https://www.ijsr.net/getabstract.php?paperid=ART20177692, DOI: https://www.doi.org/10.21275/ART20177692