International Journal of Science and Research (IJSR)

International Journal of Science and Research (IJSR)
Call for Papers | Fully Refereed | Open Access | Double Blind Peer Reviewed

ISSN: 2319-7064


Downloads: 125 | Views: 264

Research Paper | Physics Science | Ghana | Volume 8 Issue 1, January 2019 | Popularity: 6.2 / 10


     

Calibration of Survey Meters at the Secondary Standards Dosimetry Laboratory at the Radiation Protection Institute of Ghana Tomic Energy Commission

J. Owusu-Banahene, E.O Darko, P. Appiah, P. Owusu-Manteaw


Abstract: Some digital and analogue radiation surveys meter have been calibrated at the Secondary Standard Dosimetry Laboratory at Radiation Protection Institute of Ghana Atomic Energy Commission using Cs-137 radiation source. All the survey meters were a total of ten having the ratio of 2: 8 indicating 20 % were analogue whereas 80 % were digital survey meters. Calibration of radiation survey meter instruments is a process which may be conducted with varying degrees of accuracy and precision. Both are a function of the facilities and equipment, time, personnel and financial resources available to perform the calibration. Proper care of radiation detecting and measuring equipment, as with all equipment, is the primary mechanism for ensuring its proper functioning. Radiation measuring devices need to process calibration, which might lose their sensitivity and extent of the response and the amount of stability under a changing condition from time to time in which this period depends on the nature and the use of radiation field in which the device is used. For all the selected radiation survey meters brought to Secondary Standards Dosimetry Laboratory, the radiation survey meter from the company S5 had the highest response whereas the survey meter from S8, had the lowest response hence the highest calibration factor.


Keywords: Calibration, Dose rate, Radiation, Response and Instrument


Edition: Volume 8 Issue 1, January 2019


Pages: 1386 - 1391



Make Sure to Disable the Pop-Up Blocker of Web Browser




Text copied to Clipboard!
J. Owusu-Banahene, E.O Darko, P. Appiah, P. Owusu-Manteaw, "Calibration of Survey Meters at the Secondary Standards Dosimetry Laboratory at the Radiation Protection Institute of Ghana Tomic Energy Commission", International Journal of Science and Research (IJSR), Volume 8 Issue 1, January 2019, pp. 1386-1391, https://www.ijsr.net/getabstract.php?paperid=ART20194344, DOI: https://www.doi.org/10.21275/ART20194344



Similar Articles

Downloads: 223

Research Paper, Physics Science, Nigeria, Volume 8 Issue 1, January 2019

Pages: 110 - 113

Determination of Lead from Tailings of Gold Matrix using Proton Induced X-ray Emission

Buhari Samaila

Share this Article

Downloads: 2

Research Paper, Physics Science, Saudi Arabia, Volume 10 Issue 12, December 2021

Pages: 1005 - 1009

Assessment of Indoor Radon Levels in Student Lecture Halls in Umm Al Qura University, Makkah, KSA

R. A. Hassan

Share this Article

Downloads: 2 | Weekly Hits: ⮙2 | Monthly Hits: ⮙2

Analysis Study Research Paper, Physics Science, India, Volume 12 Issue 9, September 2023

Pages: 211 - 217

High Dose Gamma Radiation Induced Modifications in Chemical, Electrical and Morphological Properties of PES Polymer

Bashir Ahmed

Share this Article

Downloads: 3 | Weekly Hits: ⮙1 | Monthly Hits: ⮙2

Experimental Result Paper, Physics Science, Saudi Arabia, Volume 12 Issue 11, November 2023

Pages: 620 - 622

Testing Ammonia Borane as a Promising Non-Toxic, Lightweight, Hydrogen Rich Material for Aprons in Nuclear Medicine

Wed Alghamdi

Share this Article

Downloads: 4 | Weekly Hits: ⮙4 | Monthly Hits: ⮙4

Analysis Study Research Paper, Physics Science, India, Volume 12 Issue 9, September 2023

Pages: 396 - 401

Optical and Structural Studies of Kapton Polymer Irradiated by 1.2 MeV Gamma Radiations

Bashir Ahmed

Share this Article
Top