International Journal of Science and Research (IJSR)

International Journal of Science and Research (IJSR)
Call for Papers | Fully Refereed | Open Access | Double Blind Peer Reviewed

ISSN: 2319-7064


Downloads: 129 | Views: 305

Comparative Studies | Mechanical Engineering | India | Volume 3 Issue 12, December 2014 | Popularity: 6.8 / 10


     

Comparative Analysis of Cop Using R134a & R600a Refrigerant in Domestic Refrigerator at Steady State Condition

M.Abuzar Qureshi, Shikha Bhatt


Abstract: The aim of this project is to comparatively analyze of COP using R134a & R600a Refrigerant in Domestic refrigerator at steady state condition. Two different refrigerant are R600a (Isobutene) and R134a (tetrafluoroethae). R134a is zero ozone depletion layer and high global warning and R600a is zero ozone depletion layer and negligible global warning. In domestic refrigerator was selected by the obtained result from R134a and an experiment using 50 g of R600a which indicate the similar result as R134a. Based on outcomes R600a charge amount, condenser evaporator and compressor coefficient of performance were selected for design. The analysis of variance result is indicated that R600a charge amount was the most effective parameter. At optimum condition the amount of charge is required for R600a was 50 g, 66 % lower than R134a one, which not only being economic advantages, but also significantly reduces the of flammability of the hydrocarbon refrigerant. Thus in the present work comparatively analyze of COP using R134a & R600a Refrigerant in Domestic refrigerator at steady state condition. All the result were compared. Comparison of performance domestic refrigerator at steady state condition of the system was also studied. The result is indicate that R600a COP is mere then R134a.


Keywords: Isobutene, Energy consumption, Ozone depletion potential, Global warning potential, Coefficient of performance


Edition: Volume 3 Issue 12, December 2014


Pages: 935 - 939



Make Sure to Disable the Pop-Up Blocker of Web Browser




Text copied to Clipboard!
M.Abuzar Qureshi, Shikha Bhatt, "Comparative Analysis of Cop Using R134a & R600a Refrigerant in Domestic Refrigerator at Steady State Condition", International Journal of Science and Research (IJSR), Volume 3 Issue 12, December 2014, pp. 935-939, https://www.ijsr.net/getabstract.php?paperid=SUB14603, DOI: https://www.doi.org/10.21275/SUB14603



Similar Articles

Downloads: 4 | Weekly Hits: ⮙1 | Monthly Hits: ⮙1

Case Studies, Mechanical Engineering, Brazil, Volume 11 Issue 2, February 2022

Pages: 195 - 198

CFD Simulation of Pneumatic Valve for Energy Efficiency Studies

Evelyn Melissa Serino Monteiro, Luciana Lima Monteiro, Jose Angelo Peixoto da Costa

Share this Article

Downloads: 4 | Weekly Hits: ⮙4 | Monthly Hits: ⮙4

Research Paper, Mechanical Engineering, India, Volume 12 Issue 11, November 2023

Pages: 1829 - 1831

A Review on Study of Design Optimization Technique of Mechanical Component

Kanchan S. Gaikwad, Shekhar G. Shinde, Ranjitsinha R Gidde

Share this Article

Downloads: 56

Research Paper, Mechanical Engineering, Kosovo, Volume 10 Issue 3, March 2021

Pages: 181 - 184

Experiences in the Commercial Application of GSHP Systems in Kosovo

Mustafe Muhaxheri, Ramadan Alushaj

Share this Article

Downloads: 74 | Weekly Hits: ⮙1 | Monthly Hits: ⮙1

Research Paper, Mechanical Engineering, Albania, Volume 9 Issue 11, November 2020

Pages: 1375 - 1380

Active Chilled Beam (ACB) System, Solution with the Best Economic Life of High-Rise Buildings with High Thermal Mass and Low Cooling Capacity Load

Ramadan Alushaj, Flamur Bidaj

Share this Article

Downloads: 105 | Weekly Hits: ⮙1 | Monthly Hits: ⮙1

Research Paper, Mechanical Engineering, India, Volume 5 Issue 5, May 2016

Pages: 1897 - 1900

Energy Consumption and Optimization in Process Industries

Faraz Ahmad, Dr. R. K. Jain

Share this Article



Top