Study the Factors Affecting the Quality Assurance of Superficial RadiotherapyX-RayMachine
Allehyani S. H., Taha M.T., Bahashwan Y. M.
Abstract: The aim of this study was to analyze factors influencing the quality assurance of superficial radiotherapy X-ray machine such as dose output reproducibility, linearity, kV accuracy, time accuracy. Moreover the entrance skin dose for hand, face and nose using Perspex phantom was measured. We measured these factors and entrance skin doses using Unidose master connected with 0.2 cc soft X-Ray Chamber type 23342, which was placed above a Perspex phantom inside the chosen field size of used applicator on the couch. The reproducibility of dose output was 0.17 %, the kilo voltage accuracy percentage and time accuracy percentage were ranged from.38 to 0.87 % and -0.96 to 3.4 % respectively. Linearity of radiotherapy X-ray machine was 0.02 which lower than the tolerance limit of the American Association of physicist in Medicine reference value, the limit specified in the academic literature and international publications. The relative error for entrance skin dose equals 3 %. The entrance skin doses for face, nose and hand were 56.68 0.307, 241.2 2.15 and 60.52 0.104 mGy respectively. The tests for the quality assurance of superficial radiotherapy X-ray machine was compared and assessed with the international tolerance.
Keywords: Quality Assurance, Unidose, 02 cc Soft X-Ray Chamber
Edition: Volume 4 Issue 4, April 2015
Pages: 1316 - 1319
Make Sure to Disable the Pop-Up Blocker of Web Browser
Similar Articles
Downloads: 127
Survey Paper, Radiological Sciences, Egypt, Volume 4 Issue 3, March 2015
Pages: 372 - 375Study the Quality Assurance of Conventional X-Ray Machine using Non-Invasive KV Meter
Taha.M.T
Downloads: 133 | Weekly Hits: ⮙1 | Monthly Hits: ⮙1
Research Paper, Radiological Sciences, Sudan, Volume 4 Issue 1, January 2015
Pages: 1875 - 1878Evaluation of Diagnostic Radiology Department in Term of Quality Control (QC) of X-Ray Units at Khartoum State Hospitals
H.A.Ismail, O.A.Ali, M.A.Omer, M.E.Garelnabi, N.S.Mustafa
Downloads: 145
Research Paper, Radiological Sciences, Egypt, Volume 5 Issue 9, September 2016
Pages: 703 - 708Development of the Use of Amorphous Silicon (ASi) Electronic Portal Imaging Devices as a Physics Tool for Routine Linear Accelerator QA
Gena M.A.H, Ahmed L.El-Attar, Elbadry M. Zahran, Hany El-Gamal, Moamen M.O.M. Aly
Downloads: 148 | Weekly Hits: ⮙1 | Monthly Hits: ⮙1
Survey Paper, Radiological Sciences, Saudi Arabia, Volume 6 Issue 6, June 2017
Pages: 743 - 746Diagnostic Reference Levels as a Quality Assurance Tool for Routine X-ray Examinations in Sudan
Nagla Abdllha Mansor, Ahmed Abu Kuna, Naji I. Ali, Bader Abu Naib, Nadia S. Ali