International Journal of Science and Research (IJSR)

International Journal of Science and Research (IJSR)
Call for Papers | Fully Refereed | Open Access | Double Blind Peer Reviewed

ISSN: 2319-7064


Downloads: 105 | Views: 302

Survey Paper | Radiological Sciences | Egypt | Volume 4 Issue 4, April 2015 | Popularity: 6.4 / 10


     

Study the Factors Affecting the Quality Assurance of Superficial RadiotherapyX-RayMachine

Allehyani S. H., Taha M.T., Bahashwan Y. M.


Abstract: The aim of this study was to analyze factors influencing the quality assurance of superficial radiotherapy X-ray machine such as dose output reproducibility, linearity, kV accuracy, time accuracy. Moreover the entrance skin dose for hand, face and nose using Perspex phantom was measured. We measured these factors and entrance skin doses using Unidose master connected with 0.2 cc soft X-Ray Chamber type 23342, which was placed above a Perspex phantom inside the chosen field size of used applicator on the couch. The reproducibility of dose output was 0.17 %, the kilo voltage accuracy percentage and time accuracy percentage were ranged from.38 to 0.87 % and -0.96 to 3.4 % respectively. Linearity of radiotherapy X-ray machine was 0.02 which lower than the tolerance limit of the American Association of physicist in Medicine reference value, the limit specified in the academic literature and international publications. The relative error for entrance skin dose equals 3 %. The entrance skin doses for face, nose and hand were 56.68 0.307, 241.2 2.15 and 60.52 0.104 mGy respectively. The tests for the quality assurance of superficial radiotherapy X-ray machine was compared and assessed with the international tolerance.


Keywords: Quality Assurance, Unidose, 02 cc Soft X-Ray Chamber


Edition: Volume 4 Issue 4, April 2015


Pages: 1316 - 1319



Make Sure to Disable the Pop-Up Blocker of Web Browser




Text copied to Clipboard!
Allehyani S. H., Taha M.T., Bahashwan Y. M., "Study the Factors Affecting the Quality Assurance of Superficial RadiotherapyX-RayMachine", International Journal of Science and Research (IJSR), Volume 4 Issue 4, April 2015, pp. 1316-1319, https://www.ijsr.net/getabstract.php?paperid=SUB153341, DOI: https://www.doi.org/10.21275/SUB153341



Similar Articles

Downloads: 127

Survey Paper, Radiological Sciences, Egypt, Volume 4 Issue 3, March 2015

Pages: 372 - 375

Study the Quality Assurance of Conventional X-Ray Machine using Non-Invasive KV Meter

Taha.M.T

Share this Article

Downloads: 133 | Weekly Hits: ⮙1 | Monthly Hits: ⮙1

Research Paper, Radiological Sciences, Sudan, Volume 4 Issue 1, January 2015

Pages: 1875 - 1878

Evaluation of Diagnostic Radiology Department in Term of Quality Control (QC) of X-Ray Units at Khartoum State Hospitals

H.A.Ismail, O.A.Ali, M.A.Omer, M.E.Garelnabi, N.S.Mustafa

Share this Article

Downloads: 145

Research Paper, Radiological Sciences, Egypt, Volume 5 Issue 9, September 2016

Pages: 703 - 708

Development of the Use of Amorphous Silicon (ASi) Electronic Portal Imaging Devices as a Physics Tool for Routine Linear Accelerator QA

Gena M.A.H, Ahmed L.El-Attar, Elbadry M. Zahran, Hany El-Gamal, Moamen M.O.M. Aly

Share this Article

Downloads: 148 | Weekly Hits: ⮙1 | Monthly Hits: ⮙1

Survey Paper, Radiological Sciences, Saudi Arabia, Volume 6 Issue 6, June 2017

Pages: 743 - 746

Diagnostic Reference Levels as a Quality Assurance Tool for Routine X-ray Examinations in Sudan

Nagla Abdllha Mansor, Ahmed Abu Kuna, Naji I. Ali, Bader Abu Naib, Nadia S. Ali

Share this Article



Top