Downloads: 114 | Views: 290
Research Paper | Radiological Sciences | Lebanon | Volume 4 Issue 5, May 2015 | Popularity: 6.9 / 10
A New Transfer Technique (San Technique) of CAD/MAM Surgical Guide for Prosthetic Driven Implant
Nabeel Martani, Essam Osman, Lucette Segaan, Mohammad Rayyan
Abstract: Statement of problem there is absence of link between virtual implant planning and manually fabricated surgical guides. Purpose to design and evaluate a simple technique (San technique) to manually fabricate cast-based surgical guide derived from virtual computer aided design. Materials and methods Ten partially edentulous patients were selected for this study. The standard radiographic template were fabricated and a reference plate with three radiographic markers where attached to the occlusal surface. CBCT was acquired and virtual implant planning was performed using AccuGuide software. The virtual plan was transferred to the manually fabricated surgical guide using an innovative simple technique (San technique). The implant bed was prepared through the surgical guide utilizing UniGuide surgical kit and Bicon dental implant was installed. Post-operative CBCT was superimposed onto virtual planning to evaluate the transfer accuracy. Data were collected, tabulated and statistically analyzed. Results There was no statistically significant difference between the virtually planned and placed implants using the innovative San technique. The mean global deviation at the coronal level was 0.52 0.19, while at the apical level was 0.84 0.25 and the angular deviation was 5.14 1.31 degrees. Conclusion San technique produced acceptable functioning surgical guides. It represents a reliable convenient alternative to CAD/CAM fabricated surgical guides.
Keywords: virtual implant planning, dental implant, surgical guide, CAD/MAM
Edition: Volume 4 Issue 5, May 2015
Pages: 470 - 475
Make Sure to Disable the Pop-Up Blocker of Web Browser
Downloads: 258 | Views: 572
Radiological Sciences, Saudi Arabia, Volume 7 Issue 1, January 2018
Pages: 12 - 14Job Satisfaction of Radiographic Technologist in Sudan and the Main Reasons of Dissatisfaction
Awad Mohamed Elkhadir, Ikhlas O. Saeed
Downloads: 234 | Views: 450
Radiological Sciences, Saudi Arabia, Volume 9 Issue 1, January 2020
Pages: 283 - 287Detection of the Rotator Cuff Tendons Tears by Ultrasound in Sudanese Housewives with Chronic Shoulder Pain
Rehab Hussien Elkhair Hussien, Elgeili Adam Abdelgadir Yousif, Omar Mohammed Ali Loaz, Mohammed Abdelwahab Idriss Salih, Elfadil Faroug Abdelaal Elnour
Downloads: 228 | Views: 388
Radiological Sciences, India, Volume 9 Issue 1, January 2020
Pages: 243 - 244Role of CT Imaging to Evaluate Osteomeatal Complex in Inflammatory Lesions of Paranasal Sinus
Dr. Jainam V. Mehta, Dr. Chandra Raychaudhari
Downloads: 222 | Views: 387
Radiological Sciences, Saudi Arabia, Volume 9 Issue 1, January 2020
Pages: 350 - 352Measurements Absorbed Doses to Some Organs during Head CT Imaging
T. M. Taha, S. H. Allehyani
Downloads: 201 | Views: 354
Radiological Sciences, India, Volume 9 Issue 1, January 2020
Pages: 358 - 360Thyroid Abscess as a Complication of Tubercular Cervical Lymphadenopathy
Dr. Iram Fathima, Dr. Sreelatha, Dr. Rajani, Dr. Naveen