International Journal of Science and Research (IJSR)

International Journal of Science and Research (IJSR)
Call for Papers | Fully Refereed | Open Access | Double Blind Peer Reviewed

ISSN: 2319-7064


Downloads: 118 | Views: 264 | Weekly Hits: ⮙1 | Monthly Hits: ⮙1

Research Paper | Medicine Science | China | Volume 5 Issue 12, December 2016 | Popularity: 7 / 10


     

Experimental Investigation into the Cooling Water Distribution Parameters of a Unique Indirect Evaporative Cooler in Subway Station

Yecong He, Shan Liu


Abstract: Put forward a unique indirect evaporative cooler with rotary cooling water distribution device which is driven by a low-speed motor to solve the installation location problem of the cooling tower in subway station. This study investigates the air parameters of the Guangzhou subway stations exhaust channel in summer and winter, and optimizes the cooling water distribution method and the heat transfer performance of the indirect evaporative cooler. Results show that moving the cooling tower into the exhaust channel was feasible. Performance tests are conducted on an evaporative cooler consisting of heat exchanger coil that is cooled by a rotary cooling water distribution device, which flank spray cooling water on both sides of the coil. From the orthogonal experiment results, it is found that the air flow parallel to the normal direction of the heat exchanger, the thermal performance of heat exchanger is optimal, the water distribution devices best speed is 76 rpm, heat transfer performance increase with the mass flow rate of the cooling water and hot water, the cooling water inlet temperature and the air velocity. The increase of the water temperature and the air temperature declined the heat exchange performance, the cooling water inlet temperature change affect the heat exchange performance is the most significant, when the hot water temperature rise from 35 to 39, the heat transfer performance improved 37.62 %.


Keywords: Indirect Evaporative Cooling, Heat transfer, Subway


Edition: Volume 5 Issue 12, December 2016


Pages: 1740 - 1747



Make Sure to Disable the Pop-Up Blocker of Web Browser




Text copied to Clipboard!
Yecong He, Shan Liu, "Experimental Investigation into the Cooling Water Distribution Parameters of a Unique Indirect Evaporative Cooler in Subway Station", International Journal of Science and Research (IJSR), Volume 5 Issue 12, December 2016, pp. 1740-1747, https://www.ijsr.net/getabstract.php?paperid=23121602, DOI: https://www.doi.org/10.21275/23121602



Similar Articles

Downloads: 178 | Weekly Hits: ⮙1 | Monthly Hits: ⮙1

Research Paper, Medicine Science, China, Volume 9 Issue 3, March 2020

Pages: 983 - 985

Energy-Efficient Technology Based on Nucleate Boiling Heat Transfer

Zhiyi Duan, Tao Jia, Di Gao, Zhigang Cui

Share this Article

Downloads: 128 | Weekly Hits: ⮙1 | Monthly Hits: ⮙1

Research Paper, Medicine Science, Tunisia, Volume 7 Issue 3, March 2018

Pages: 1638 - 1645

Heat Transfer Behavior of Al2O3-Water Nanofluid in Confined Cavity Heated From the Bottom

Houda Jalali, Hassen Abbassi

Share this Article

Downloads: 132

M.Tech / M.E / PhD Thesis, Medicine Science, India, Volume 8 Issue 1, January 2019

Pages: 1154 - 1156

Investigation of Natural Fiber Composite Material for Building Cooling System

Gowtham, Rajakumar

Share this Article



Top