Downloads: 126 | Views: 330
M.Tech / M.E / PhD Thesis | Civil Engineering | India | Volume 5 Issue 10, October 2016 | Popularity: 6.9 / 10
Seismic Analysis of RC Frame with the Variation of Position of Soft Storey
Vikram Singh Kushwah, Ravi Dwivedi
Abstract: Uncertainties involved and behavior studies are vital for all civil engineering structures. Many buildings in the present scenario have irregular configurations both in plan and elevation. The objective of the paper is to carry out Equivalent static analysis of vertically irregular RC building frames in which Stiffness irregularity was considered for different stories at a time. These irregularities are provided as per clause 7.1 of IS 1893 (part1) 2002 code. According to our observation in case of displacement for all the position of soft storey excluded ground position, top 3 storey positions for soft storey should be safer as compare to middle storey position of soft storey. In case of maximum stresses in column for all positions of soft storey excluded ground storey give same result (approx. ) except 3rd position of soft storey. So position soft storey at 3rd is most unsafe for structure in case of stresses in column. In case of maximum stresses in beam for all positions of soft storey excluded ground storey if middle storeys of structure are soft than beams are more stressed as compare to position at top and bottom storeys. In case of maximum shear force in beam for all positions of soft storey excluded ground storey give same result (approx. ) except 1st position of soft storey. So position of soft storey at 1st is most unsafe for structure in case of shear force in beam. In case of storey drift for all positions of soft storey excluded ground storey give same result (approx. ) except 1st position of soft storey. So position of soft storey at 1st is most unsafe for structure in case of storey drift. For all the cases displacement, stresses, shear force and storey drift we found that top 3 positions in the stiffness irregular structure are most safer position of the soft storey in the structure. Soft computing tool and commercial software staad. pro V8i (select series 5) is used for modeling and analysis.
Keywords: Static, Seismic, RC Frame, Stiffness irregularity, IS 1893 part1 2002, Soft storey
Edition: Volume 5 Issue 10, October 2016
Pages: 1073 - 1080
Make Sure to Disable the Pop-Up Blocker of Web Browser
Similar Articles
Downloads: 114
Research Paper, Civil Engineering, Iraq, Volume 6 Issue 4, April 2017
Pages: 2398 - 2405Experimental Behavior of Laced Reinforced Concrete Beams under Static Loading
Hayfaa Dhumad Hasan Al-Abboodi, Abass Abdulmajeed Allawi, Chai Hwa Kian
Downloads: 0
Review Papers, Civil Engineering, India, Volume 11 Issue 7, July 2022
Pages: 1230 - 1233Analysis of a Multistorey Building Resting on Sloping Ground in Different Seismic Zone and Comparison of Results
Vishal K. Gongale, Ganesh Mahalle
Downloads: 8 | Weekly Hits: ⮙1 | Monthly Hits: ⮙2
Research Paper, Civil Engineering, India, Volume 10 Issue 7, July 2021
Pages: 213 - 223Effect of Shear Wall in Seismic Performance of High-Rise Irregular RC Framed Building
Yagya Raj Khatri, Dr. Prasenjit Saha
Downloads: 36
Research Paper, Civil Engineering, India, Volume 10 Issue 3, March 2021
Pages: 720 - 731Analysis and Design of Elevated Intez Water Tank based on Normal Frame Staging Subjected to Seismic Loading by Using StaadPro Software
Venkata Raju Badanapuri
Downloads: 87
Research Paper, Civil Engineering, India, Volume 10 Issue 2, February 2021
Pages: 86 - 96Static and Dynamic Analysis of Multistoried Building in Seismic Zone-III
Venkata Raju Badanapuri