International Journal of Science and Research (IJSR)

International Journal of Science and Research (IJSR)
Call for Papers | Fully Refereed | Open Access | Double Blind Peer Reviewed

ISSN: 2319-7064


Downloads: 120

Research Paper | Biotechnology | Volume 6 Issue 9, September 2017 | Pages: 1629 - 1634 | India


Clinical Performance Characteristics of Hepatitis B Virus Quantification by Combining Artus-DSP Assay with Rotor Gene Q-Real-Time PCR

Kandpal JC, Kumar R, Kumar V, Singh PR

Abstract: Background A simple and reliable DNA extraction & quantification method of hepatitis B virus (HBV) is critical in developing a viral load measurement for HBV infection. Current commercially available plasma Hepatitis B Virus (HBV), DNA extraction & quantification methods are less sensitive and require optimization, which restrict wide adoption in clinical laboratories. This study offers a report on the quantitative viral load- artus HBV RG PCR assay by combining QIAamp DSP Plasma DNA extraction with Rotor gene Q-Real-time PCR (Rotor gene Q-PCR). Methods Plasma was separated by centrifugation after collection of whole peripheral blood, which was then stored at -200 C until process. DNA was extracted as per instruction & guidelines of manufacturer. The recovered eluted DNA was mixed into PCR master-mix. The Q-PCR assay performance, including linearity, diagnostic accuracy and reliability were determined. Viral load compared of the no viral load, low viral titer & high viral titer from the clinical samples for evaluation Results The average % yield for HBV DNA standards used was within in the range (SD 0.04 to 0.13, CV % 0.97 to 2.22). The coefficient of variation (CV) of HBV quantification for low and high titer samples was 2.23 % and 2.37 %, respectively. The real-time assay linearity was demonstrated with a slope of -3.03 to -3.50 and R2 values of 0.98 to 0.99. Accuracy and reliability of the Rotor gene Q-PCR assay was confirmed with the reference panel, and there was a strong correlation between the two results (R2 = 0.99,

Keywords: Hepatitis B Virus, Quantitative Standards, DNA amplification, Taqman Technology

How to Cite?: Kandpal JC, Kumar R, Kumar V, Singh PR, "Clinical Performance Characteristics of Hepatitis B Virus Quantification by Combining Artus-DSP Assay with Rotor Gene Q-Real-Time PCR", Volume 6 Issue 9, September 2017, International Journal of Science and Research (IJSR), Pages: 1629-1634, https://www.ijsr.net/getabstract.php?paperid=ART20176971, DOI: https://dx.doi.org/10.21275/ART20176971

Download Citation: APA | MLA | BibTeX | EndNote | RefMan

Share This Research

Help this article reach readers, researchers and professionals.

Share activity is measured for research-engagement analytics. Only verified, unique public shares can support award tie-breaking.

Confirm Your Share

Enter your details so IJSR can confirm this sharing activity.

Your details are used to validate this share and protect the award process from duplicate or false activity.

Download Article PDF


Rate This Article!

Top

Confirm Your Share

Enter your details so IJSR can confirm this sharing activity.

Your details are used to validate this share and protect the award process from duplicate or false activity.