Downloads: 140 | Views: 284
Research Paper | Electrical Engineering | India | Volume 7 Issue 5, May 2018 | Popularity: 6.7 / 10
Transient Stability Enhancement of Hybrid Power System with Wind Generator
Surbhi Sharma, Anant Thakur
Abstract: Flexible AC transmission systems (FACTS) controllers have been mainly used to solve various power system control problems. Many controllers of Flexible AC Transmission Systems (FACTS) like SVC, STATCOM, Unified Power Flow Controller (UPFC), PWM asynchronous dc link, Thyristor-Controlled Series Capacitor (TCSC) and PWM Series Static VAR compensator gives stabilized voltage support. So they can be placed at the mid-point of the transmission line, which has been proven by the late E. W. Kimbark, as the optimum location for shunt capacitor compensation. In this paper a shunt FACTS device (STATCOM) on transmission line to improve transient stability with predefined real power flow. Voltage stability is a key issue to achieve the uninterrupted operation of wind farms equipped with squirrel cage induction generators (SCIG) during grid faults. A Static Synchronous Compensator (STATCOM) is applied to a power network which includes a SCIG driven by a wind turbine, for steady state voltage regulation and transient voltage stability support. The system is implemented using MATLAB/ SIMULINK. Results illustrate that the STATCOM improves the transient voltage stability and therefore helps the wind turbine generator system to remain in service during faults.
Keywords: Transient Stability, FACTS Device, PSS, Wind Generator
Edition: Volume 7 Issue 5, May 2018
Pages: 1249 - 1252
Make Sure to Disable the Pop-Up Blocker of Web Browser
Similar Articles
Downloads: 107
Case Studies, Electrical Engineering, Iraq, Volume 6 Issue 6, June 2017
Pages: 2579 - 2583Use Series Compensation in Distribution Networks 33 KV
Dr. Al-Zohuariali M. Kathim, Majeed R. Zaidan
Downloads: 110
Research Paper, Electrical Engineering, India, Volume 5 Issue 5, May 2016
Pages: 1553 - 1556Transient Stability Improvement using FACTS Devices
Pradeepkumar S. Mahapure, A. R. Soman
Downloads: 111
Research Paper, Electrical Engineering, India, Volume 5 Issue 1, January 2016
Pages: 1003 - 1007Harmonic& Transient Stability Analysis of GIS TRANSCO Network Using ETAP
Deepak Kumar Goyal, Abhishek Chaturvedi
Downloads: 114
Research Paper, Electrical Engineering, India, Volume 5 Issue 5, May 2016
Pages: 2191 - 2197Improvement of Power System Transient Stability Using Fuzzy Controlled Shunt Facts Device
B. Gopal Reddy, Kamaldeep Sharma
Downloads: 115
Research Paper, Electrical Engineering, India, Volume 3 Issue 9, September 2014
Pages: 627 - 633Reactive Power Control of Permanent-Magnet Synchronous Wind Generator using Matrix Converter for Grid and Standalone Applications
Priyanka Radhakrishnan, Sujan Kumar