International Journal of Science and Research (IJSR)

International Journal of Science and Research (IJSR)
Call for Papers | Fully Refereed | Open Access | Double Blind Peer Reviewed

ISSN: 2319-7064


Downloads: 59 | Views: 220

Research Paper | Electrical & Electronics Engineering | India | Volume 9 Issue 12, December 2020 | Popularity: 6.7 / 10


     

Variance Index of Three Phase Instantaneous Power based Fault during Power Swing

Prasanth Gullinka, Kumarraja.A


Abstract: Distance relays are intended to operate reliably and secured manner, and are rigorously complied with to eschew mal-operation during stressed condition. To eschew these conditions, power swing blocking functions (PSB) is included in the distance relay design. But, any kind of fault is commencing during swing, the PSB function should unblock it and provides trip signal to the circuit breakers (CB). Unsymmetrical fault cases were facilely unblocked, except in the case of symmetrical fault during power swing condition is a difficult task for relay unblocking due to balanced phenomenon. Variance indexes of three phase instantaneous power signal (VITPIP) predicated symmetrical fault detection during power swing is presented in this paper. The method utilizes quantified three-phase voltage and current signals from relay end. Extraction of high frequency components of three-phase instantaneous power signals utilizing DWT. Subsequently, variance index is estimated for the details coefficients of power signals avails to discriminate the symmetrical fault from swing event. To validate the accuracy of the proposed technique, a 400 kV, 50 Hz single machine illimitable bus system is considered and simulated in the MATLAB / SIMULINK platform. Different critical cases such as fault inception time, slip frequency, fault resistance and fault location were considered for the simulation. The results, it illustrates that the proposed method is more efficient.


Keywords: Distance relay, Transmission lines, Three-phase instantaneous power signal, Symmetrical fault, Power swing, Wavelet transform, Variance estimation


Edition: Volume 9 Issue 12, December 2020


Pages: 1057 - 1060



Make Sure to Disable the Pop-Up Blocker of Web Browser




Text copied to Clipboard!
Prasanth Gullinka, Kumarraja.A, "Variance Index of Three Phase Instantaneous Power based Fault during Power Swing", International Journal of Science and Research (IJSR), Volume 9 Issue 12, December 2020, pp. 1057-1060, URL: https://www.ijsr.net/getabstract.php?paperid=SR201218132504, DOI: https://www.doi.org/10.21275/SR201218132504



Downloads: 173 | Views: 330

Electrical & Electronics Engineering, India, Volume 9 Issue 4, April 2020

Pages: 257 - 260

Design and Simulation of Reactive Power Compensator Using STATCOM for Wind Power Plant

Mahesh.R


Downloads: 136 | Views: 282

Electrical & Electronics Engineering, India, Volume 9 Issue 5, May 2020

Pages: 148 - 151

Load Prioritization with Suspicion Assessment Based Inspection [SAI] Algorithm

Ahla A


Downloads: 135 | Views: 301

Electrical & Electronics Engineering, Bangladesh, Volume 3 Issue 1, January 2014

Pages: 84 - 87

Construction of Microcontroller Based Digital Voltmeter

Md. Imran Hossain Jony, Md. Moshiur Rahman


Downloads: 134 | Views: 306

Electrical & Electronics Engineering, India, Volume 9 Issue 5, May 2020

Pages: 1203 - 1208

A Fully Automated Lawn Cutter Using Solar Panel

Ramya P, Shailendra Kumar, Yogesh Sharma, Hitesh Ritolia, Kondeti Veerendra


Downloads: 133 | Views: 278

Electrical & Electronics Engineering, India, Volume 2 Issue 6, June 2013

Pages: 409 - 415

To Compensate AC loads using DSTATCOM

T. Srikanth