International Journal of Science and Research (IJSR)

International Journal of Science and Research (IJSR)
Call for Papers | Fully Refereed | Open Access | Double Blind Peer Reviewed

ISSN: 2319-7064


Downloads: 148 | Views: 305

Research Paper | Radiological Sciences | Saudi Arabia | Volume 9 Issue 2, February 2020 | Popularity: 6.7 / 10


     

Assessment of Effective Dose by Indirect Method for Some CT Examinations in Medical Imaging Department

T. M. Taha, R. A. Kutbi


Abstract: Purpose to assess the radiation doses, diagnostic reference level, dose length product (DLP) and effective doses for CT examinations in one of medical imaging department in Jeddah, SA. Materials and Methods. Dose diagnostic reference levels are calculated as the third quartile value of the distribution of the dose descriptors observed in patient dose surveys. Effective doses (E) for brain, sinuses and abdomen CT examination are estimated using DLP dose conversion Coefficients. Results The mean DRL (mGy), DLP (mGy. cm) and effective doses for brain, sinuses and abdomen examination are compared to surveys from international countries for 96 patients from king Abdullah medical complex, Jeddah. The mean (minimum-maximum) radiation doses were, as follows: for Brain examinations 49 (32-58) mGy, 508 (276-1133) mGy. cm and 1.17 mSv, respectively; for Sinuses examinations 3.5 (1.4-4) mGy, 89 (29-85) mGy. cm and 0.21 mSv, respectively and for Abdomen examinations 14 (7-10) mGy, 807 (263-1960) mGy. cm and 12.11 mSv, respectively. These results are compared with diagnostic reference dose levels the European Commission are within diagnostic reference levels. Conclusion CT in the mentioned hospital in Saudi Arabia associated with relatively low radiation doses in third quartile, 75 % of the patients size due to use radiation dose reduction software.


Keywords: Computed tomography, diagnostic reference dose levels, length product, Effective doses


Edition: Volume 9 Issue 2, February 2020


Pages: 457 - 459



Make Sure to Disable the Pop-Up Blocker of Web Browser




Text copied to Clipboard!
T. M. Taha, R. A. Kutbi, "Assessment of Effective Dose by Indirect Method for Some CT Examinations in Medical Imaging Department", International Journal of Science and Research (IJSR), Volume 9 Issue 2, February 2020, pp. 457-459, https://www.ijsr.net/getabstract.php?paperid=SR20203044020, DOI: https://www.doi.org/10.21275/SR20203044020



Similar Articles

Downloads: 113

Research Paper, Radiological Sciences, Saudi Arabia, Volume 5 Issue 10, October 2016

Pages: 1135 - 1136

Evaluation of Radiation Dose for Computed Tomography of Kidney Ureter and Bladder Protocol

Mogahid M. A Zidan, Ikhlas A. Hassan, Abdelrahaman M. Elnour, Wadah M. Ali

Share this Article

Downloads: 121

Research Paper, Radiological Sciences, Sudan, Volume 4 Issue 2, February 2015

Pages: 2422 - 2424

Valuation of Radiation Dose in Lumbosacral Examination

Yousif Mohamed Y. Abdallah, Maryem Milad Hemair, Amel S. Algaddal

Share this Article

Downloads: 145

Survey Paper, Radiological Sciences, Saudi Arabia, Volume 7 Issue 8, August 2018

Pages: 488 - 492

Assessment of Radiation Dose from CT to Workers and Public from Common Diagnostic Investigations in Qatif Hospital

Fahad A. Mohamed, Gamareldein Alshikh, Mustafa Almeshal, Hassan AL-Sawad, Salman AL-faraj

Share this Article

Downloads: 151

Research Paper, Radiological Sciences, Sudan, Volume 4 Issue 10, October 2015

Pages: 262 - 265

Estimation of Radiation Dose Received in Skull X-Rays in Emergency Radiology Department

Yousif Mohamed Y. Abdallah, Noora E. Omer, Nesrin A. M. Mohamoud, Mashal Abdallah

Share this Article



Top