Downloads: 3 | Views: 166
Research Paper | Ophthalmology | India | Volume 10 Issue 9, September 2021 | Popularity: 5.2 / 10
A Study on Repeatability and Agreement of Keratometry & Refractive Prediction between Verion and IOL Master
Kaksha Desai, Riddhi Shah
Abstract: Purpose: The aimed to analyse the predictability of the instrument for calculation of IOL power and K reading on VERION planner and to check the verion predicted refractive power or final follow - up refractive power. Methodology: From March 2020 to July2021, a retrospective investigation was done at the Rotary Eye Institute in Navsari. The study included 120 eyes, both preoperatively and postoperatively, from people who had cataract surgery (phacoemulsification). The patients were assessed on both machines by the same examiner during each individual pre - assessment, and then followed up on the VERION image - guided system as well as the IOL master roughly 2 months after surgery by the same examiner. The calculation for the predictive spherical outcomes for both the IOL Master and VERION systems. Then both IOL Master IOL power and verion IOL power and the VERION Predicted refractive power and after final follow up refractive power were compared using SPSS software. Result: Pre - operative IOL K1 (43.42 ? 1.94) was almost same significantly (p<0.01) VERION K1 value (43.42 ? 1.94). Pre - operative IOL K2 (43.31 ? 2.07) was significantly same as the VERION K2 (43.40 ? 2.07). Pre - operative VERION predicted refractive status (SPH & CYL) in 2.2mm incision ( - 0.15 ? 0.12) ( - 0.70 ? 0.54) was decreases (- 0.04 ? 0.20) (- 0.49 ? 0.60) significantly after Final follow - up. Pre - operative VERION predicted refractive status (SPH & CYL) in 2.8mm incision (- 0.18 ? 0.11) (- 0.93 ? 0.56) was decreases ( - 0.07 ? 0.21) ( - 0.88 ? 0.96) significantly after Final follow - up. Pre - operative VERION predicted refractive status (SPH & CYL) in 3.0mm incision (- 0.17 ? 0.10) (- 0.76 ? 0.54) was decreases (-0.13 ? 0.33) (- 0.88 ? 0.96) significantly after Final follow - up. The correlation between two (IOL master 500 & VERION) for determining pre - operative keratometry reading demonstrated a high relationship between the pre - operative K1 of IOL master & VERION (p<0.01, r=0.975) and pre - operative K2 of IOL master & VERION (p<0.01, r=0.981). The correlation between (IOL master, VERION and IOL implanted power) demonstrated a medium relationship between the IOL master power and VERION power (p<0.01, r=0.679) & a high relationship between the IOL master and IOL implanted power (p<0.01, r=0.954) & a high relationship between the VERION and IOL implanted power (p<0.01, r=0.748). Conclusion: After the two months final follow - up the Sph&Cyl power are decreased then the VERION predicted refractive power but the cylinder power was almost same as the VERION predicted power. The analysis suggests that there was a statistically correlation between IOL master and VERION.
Keywords: VERION planner, IOL master 500, cataract, IOL power, K reading, post - operative spherical outcome
Edition: Volume 10 Issue 9, September 2021
Pages: 682 - 686
DOI: https://www.doi.org/10.21275/SR21913132341
Make Sure to Disable the Pop-Up Blocker of Web Browser
Similar Articles
Downloads: 0
Research Paper, Ophthalmology, India, Volume 11 Issue 9, September 2022
Pages: 1181 - 1183Quality of Life after Cataract Surgery in Elderly Population
Dr. Siddharth Sharma
Downloads: 0
Informative Article, Ophthalmology, India, Volume 11 Issue 11, November 2022
Pages: 325 - 326A Case of Pupillary Block in Pseudophakia
Harshitha Gogineni, Malleswari Medikonda
Downloads: 1
Survey Paper, Ophthalmology, India, Volume 10 Issue 6, June 2021
Pages: 355 - 360Cataract Operations by Arvind Medicos Services: Attempts for Awareness and Brining Hope for Commoner from Tamil Nadu, to Enjoy Life, Colors and for Well-being
Dr. Priyanka P. Parihar, Dr. Haripriya A, Dr Sathya Ravilla
Downloads: 1
Research Paper, Ophthalmology, India, Volume 11 Issue 2, February 2022
Pages: 706 - 711To Compare Changes in Intraocular Pressure in Glaucomatous and Non Glaucomatous Subjects Pre and Post Phacoemulsification
Akanksha Nirala, Vimlesh Sharma, Shanti Pandey, Nitin Mehrotra
Downloads: 1 | Weekly Hits: ⮙1 | Monthly Hits: ⮙1
Research Paper, Ophthalmology, Indonesia, Volume 11 Issue 2, February 2022
Pages: 760 - 764An Overview of the Quality of Life of Cataract Patients after Cataract Surgery at the Tabanan Regional General Hospital
Hindrata Aditia Esmond, I Putu Rustama Putra, Ni Wayan Sedani, Cynthia Dewi M