International Journal of Science and Research (IJSR)

International Journal of Science and Research (IJSR)
Call for Papers | Fully Refereed | Open Access | Double Blind Peer Reviewed

ISSN: 2319-7064


Downloads: 127 | Views: 318

Survey Paper | Radiological Sciences | Egypt | Volume 4 Issue 3, March 2015 | Popularity: 6.2 / 10


     

Study the Quality Assurance of Conventional X-Ray Machine using Non-Invasive KV Meter

Taha.M.T


Abstract: This study was carried out to obtain optimum operation conditions for X-ray machines. We investigated some factors affecting on quality assurance of conventional Siemen X-ray machine, in one of Mansoura Hospitals such as reproducibility of dose output, time and applied high voltage, Kilo-voltage accuracy, mA accuracy, time accuracy, and linearity. We measured these factors using Non-Invasive kilo voltage meter, The NERO Max 8000 connected with suitable ionization chambers that located at 100 cm source to image detector. Reproducibility of dose output was ranged from 0.1 to 0.7 %, of time was ranged from 0.2 to 3.1 and of high voltage was ranged from 0.1 % to 0.7 % which is lower than the tolerance limit of the American Association of Physicist in Medicine reference values. Kilo-voltage accuracy percentage was ranged from 1.5 to 3.5 % and time accuracy percentage was ranged from 0.5 to 4.1 % respectively. This study concluded that as the kilo-voltage increases by one, the dose increases by 28 %.


Keywords: Quality Assurance, Reproducibility, Diagnostic X-ray, NeroMax 8000


Edition: Volume 4 Issue 3, March 2015


Pages: 372 - 375



Make Sure to Disable the Pop-Up Blocker of Web Browser




Text copied to Clipboard!
Taha.M.T, "Study the Quality Assurance of Conventional X-Ray Machine using Non-Invasive KV Meter", International Journal of Science and Research (IJSR), Volume 4 Issue 3, March 2015, pp. 372-375, https://www.ijsr.net/getabstract.php?paperid=SUB152003, DOI: https://www.doi.org/10.21275/SUB152003



Similar Articles

Downloads: 105

Survey Paper, Radiological Sciences, Egypt, Volume 4 Issue 4, April 2015

Pages: 1316 - 1319

Study the Factors Affecting the Quality Assurance of Superficial RadiotherapyX-RayMachine

Allehyani S. H., Taha M.T., Bahashwan Y. M.

Share this Article

Downloads: 133 | Weekly Hits: ⮙1 | Monthly Hits: ⮙1

Research Paper, Radiological Sciences, Sudan, Volume 4 Issue 1, January 2015

Pages: 1875 - 1878

Evaluation of Diagnostic Radiology Department in Term of Quality Control (QC) of X-Ray Units at Khartoum State Hospitals

H.A.Ismail, O.A.Ali, M.A.Omer, M.E.Garelnabi, N.S.Mustafa

Share this Article

Downloads: 145

Research Paper, Radiological Sciences, Egypt, Volume 5 Issue 9, September 2016

Pages: 703 - 708

Development of the Use of Amorphous Silicon (ASi) Electronic Portal Imaging Devices as a Physics Tool for Routine Linear Accelerator QA

Gena M.A.H, Ahmed L.El-Attar, Elbadry M. Zahran, Hany El-Gamal, Moamen M.O.M. Aly

Share this Article

Downloads: 148 | Weekly Hits: ⮙1 | Monthly Hits: ⮙1

Survey Paper, Radiological Sciences, Saudi Arabia, Volume 6 Issue 6, June 2017

Pages: 743 - 746

Diagnostic Reference Levels as a Quality Assurance Tool for Routine X-ray Examinations in Sudan

Nagla Abdllha Mansor, Ahmed Abu Kuna, Naji I. Ali, Bader Abu Naib, Nadia S. Ali

Share this Article

Downloads: 151

Research Paper, Radiological Sciences, Sudan, Volume 4 Issue 10, October 2015

Pages: 262 - 265

Estimation of Radiation Dose Received in Skull X-Rays in Emergency Radiology Department

Yousif Mohamed Y. Abdallah, Noora E. Omer, Nesrin A. M. Mohamoud, Mashal Abdallah

Share this Article



Top